200m3/H UV Water Sterilizer Equipment Waste Water Disinfection System

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-06 03:54

  • Browse the number:

    187

Send an inquiries

Company Profile

Jiangsu YLD Water Processing Equipment Co., Ltd.

By certification [File Integrity]

Contact:Miss Mint Shi(Mr.)  

Email:

Telephone:

Phone:

Area:Jiangsu

Address:Jiangsu

Website: http://yldwater.byshaiwang.com/

Product details

200m3/h UV water sterilizer Equipment Waste water disinfection system
Application
1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10. Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
12. Agricultural water disinfection

Typical Maintenance Requirements
UV lamps (bulbs) require annual replacement to ensure optimal performance. UV lamp performance, just like any other light source, will slowly diminish over time. Beyond one year, there is no assurance that the UV light emitted from the bulb will provide sufficient disinfection. Remember, UV light cannot be seen. The bulb may still produce light, but not necessarily UV rays. The quartz sleeve does not need replacement unless it gets broken, however, it should be cleaned several times per year (outside only).


BENEFITS OF UV WATER TREATMENT
Ultraviolet Water Treatment Systems don't use chemicals and don't produce harmful by-products
UV Water Treatment Systems are an economical way to eliminate health risks from unsafe drinking water
UV Water Filter Systems guarantee delivery of safe and clean water to homes and industries
UV Water Filter Combinations provide clean and safe drinking water to every tap and point of use
UV Water Sterilization Systems deactivate pathogens and parasites such as salmonella, E coli and giadia
Tank Water UV Treatment Systems sterilize rain water and bore water naturally as nature intended
UV Systems are easily incorporated with Water Softeners, Tank Water Filtration Systems, whole house, residential, Industrial-Commercial Water Filters, and deep bed water filtration systems


Principle of Operation
UV water disinfection system design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber. The dosage, as it applies to UV disinfection, is a function of time and the intensity of UV radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The UV intensity is the amount of energy, per unit time, emitted by germicidal lamp. The Dosage is the product of UV intensity and the exposure time.

Limitation of Use
The UV water disinfection system NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.

Water Quality (in)
Water quality plays a major role in the transmission of germicidal UV rays. It is recommended that the water does not exceed following maximum concentration levels

Maximum Concentration Levels (Very Important)
Iron≤ 0.3ppm(0.3mg/L)
Hardness≤ 7gpg(120mg/L)
Turbidity≤ 1NTU
Manganese≤ 0.05ppm(0.05mg/L)
Tannins≤ 0.1ppm(0.3mg/L)
UV Transmittance≥ 750‰

Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the UV transmission is not satisfactory, contact the factory.
UV wavelength (nm)

DOSAGE is the product of intensity & time
Dosage=intensity*time=micro watt/cm2*time=microwatt-seconds per square centimeter
(μ W-s/cm2)
Note: 1000μ W-s/cm2=1mj/cm2(milli-joule/cm2)

As a general guideline, the following are some typical UV transmission rates (UVT)
City water supplies850-980‰
De-ionized or Reverse Osmosis water950-980‰
Surface waters(lakes, rivers, etc)700-900‰
Ground water(wells)900-950‰
Other liquids10-990‰
model Processing capacity (Ton/Hour) power (W)  inlet and outlet
(inch)
working pressure (Kg/cm 2 ) malfunction alert for UV lamp reactor dimension (cm) L×W×H dimension of panel(cm) anchor bolt (cm) overall weight (Kg)
YLCn-005 0.3 16 1/2" 6 matched 30×6×11     5
YLCn-008 1 25 1/2" 6 matched 47×6.3×11     10
YLCn-050 2 40 1" 6 matched 100×9×20 Φ8.9×25
(diameter×length)
69×4×Φ1 25
YLCn-150 6 80 1+1/4" 6 matched 100×11×23 69×4×Φ1 30
YLCn-200 8 120 1+1/2" 6 matched 100×15.9×30 Φ8.9×45
(diameter×length)
69×7×Φ1 35
YLCn-300 12 160 2" 6 matched 100×15.9×32 69×7×Φ1 40
YLC-050 2 40 DN25/1" 6 matched 100×8.9×30 25×30×12
(L×H×w)
60×4×Φ1 45
YLC-150 6 80 DN32/1 1/4 " 6 matched 100×10.8×30 60×4×Φ1 50
YLC-200 8 120 DN40/1 1/2 " 6 matched 100×15.9×40 60×7×Φ1 60
YLC-300 12 160 DN50/2" 6 matched 100×15.9×40 60×7×Φ1 70
YLC-360 15 200 DN65/2 1/2" 6 matched 100×15.9×40 50×78×25
(L×H×W)
60×7×Φ1 120
YLC-500 20 240 DN65/2 1/2" 6 matched 100×21.9×50 60×11×Φ1.2 130
YLC-600 25 280 DN80/3" 6 matched 100×21.9×50 60×11×Φ1.2 140
YLC-700 30 320 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 150
YLC-1000 40 360 DN100/4" 6 matched 100×21.9×50 60×11×Φ1.2 160
YLC-1200 50 400 DN125/5" 6 matched 100×21.9×50 60×11×Φ1.2 180
YLC-1500 60 420 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 210
YLC-2000 80 560 DN150/6" 6 matched 170×27.3×57 120×16×Φ1.4 220
YLC-2500 100 700 DN150/6" 6 matched 170×27.3×57 60×128×30
(W×H×T)
 
120×16×Φ1.4 275
YLC-3000 125 840 DN150/6" 6 matched 173×27.3×57 120×16×Φ1.4 300
YLC-4000 150 1120 DN200/8" 6 matched 173×32.5×65 120×20×Φ1.6 325
YLC-5000 200 1400 DN200/8" 6 matched 173×37.7×72 120×22×Φ1.6 350
YLC-7000 300 2100 DN250/10" 6 matched 175×42.6×80 120×24×Φ2.0 400
YLC-10K 400 2520 DN250/10" 6 matched 176×52.9×95 60×150×40
(W×H×T)
120×28×Φ2.2 475
YLC-15K 600 3080 DN300/12" 6 matched 176×78×110 120×32×Φ2.4 600
YLC-20K 800 3920 DN350/14" 6 matched confirmed  confirmed confirmed confirmed
YLC-25K 1000 4760 DN350/14" 6 matched confirmed confirmed confirmed


Frequently Asked Questions About Ultraviolet (UV) Purification
1. What is UV? 
Ultraviolet (UV) light is at the invisible, violet end of the light spectrum. Even though we can't see UV light, we are exposed to UV rays from all light sources, including the sun.

2. How does ultraviolet light purify water? 
UV-C rays penetrate the cells of harmful bacteria and viruses in our drinking water, destroying their ability to reproduce. Without this ability, these organisms die and no longer pose a health threat. It is a simple but very effective process, with the system destroying 99.99% of harmful microorganisms.

3. Why not use chlorine instead? 
Chlorine changes the taste and odor of water. Chlorinating also produces harmful by-products called Trihalomethanes (THMs) which are linked to incidence of cancer.

4. Does a UV system use a lot of energy? 
No, the UV unit will use about the same amount of energy as a 60 watt light bulb. It is a cost effective, natural way to increase water quality.

5. Why do UV purifiers require sediment pre-filtration? 
UV systems require pre-filtration to maintain effectiveness as sediment and other contaminants in the water can create a "shadow" which prevents the UV rays from reaching and disinfecting the harmful microorganisms.

6. How often does the UV light bulb (lamp) need to be replaced? 
It is essential that you change your UV lamp annually. The ability of the lamp to emit UV light decreases over one year in operation. Remember - UV light is invisible! Even though the lamp is still glowing after one year, there might not be enough UV light reaching your water to be effective.

7. How often do your need to replace the sleeve? 
The sleeve doesn't need to be replaced unless it is broken, but it will need to be cleaned several times a year in order to keep the bulb effective in delivering high water quality.