The SS71XX series high voltage withstand and insulation teter( HI-POT tester) is used for testing insulation grade and withstanding voltage capability of electrical equiment, transformers, motor, relays, cables, electronic components, electronics applications, inductors, ignition coils, insulation wires, insulation tapes, valve coils, reactors,contactors, etc. .
Features :
Compact size and light weight
Four test modes available, W, I, W-I, I-W
Linkable to Ground Bond Tester
Capable of storing 5sets of testing conditions
Electronic ramp up and dwell time for up to 999.9 seconds
Front panel lockout
Built-in PLC Remote interface
Front panel software calibration
Easy to operate
 

Model
SS7122 SS7120 SS7112 SS7110
AC WITHSTAND VOLTAGE
Output Rating 5KVAC/12mA
Output Voltage, KVAC Range Resolution Accuracy
0-5.00 0.01 ± (2% of setting + 5V)
Output Frequency 50Hz/60Hz ± 100ppm, User Selection
Output Waveform Sine Wave, THD. < 2% (Resistive Load), Crest Factor = 1.3 - 1.5
Output Regulation ± (1% of output + 5V), From no load to full load
SETTINGS
Hi-Limit AC Current, mA 0.10 - 12.00 0.01 ± (2% of setting + 2counts)
Lo-Limit AC Current, mA 0.00 - 12.00 0.01 ± (2% of setting + 2counts)
Ramp Time, second 0.1 - 999.9 0.1 ± (0.1% + 0.05sec)
Dwell Time, second 0, 0.2 - 999.9 ( 0=continuous) 0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
DC WITHSTAND VOLTAGE (7120, 7122 ONLY)
Output Rating 6KVDC/5mA
Output Voltage, KVDC 0 - 6.00 0.01 ± (2% of setting + 5V)
Output Ripple < 5%(6KV/5mA at Resistive Load)
SETTINGS
Hi-LimitDCCurrent, mA 0.02 - 5.00 0.01 ± (2% of setting + 2counts)
Lo-LimitDCCurrent, mA 0.00 - 5.00 0.01 ± (2% of setting + 2counts)
Ramp Time, second 0.1 - 999.9 0.1 ± (0.1% + 0.05sec)
Dwell Time, second 0, 0.2 - 999.9 (0=continuous) 0.1
Arc Detection 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity)
Discharge Time < 200 msec
INSULATION RESISTANCE (7112, 7122 ONLY)
Output Rating 1KVDC/1000MΩ
Output Voltage, KVDC 0.10 - 1.00 0.01 ± (2% of setting + 2V) 
SETTINGS
Hi-Limit Resistance, MΩ 0, 1 - 1000 (0=OFF) 1 ± (3% of setting+2counts)at > 500VDC ± (7% of setting +2counts)at < 500VDC
Lo-Limit Resistance, MΩ 1 - 1000 1
Delay Time, second 0, 0.5 - 999.9 (0=continuous) 0.1 ± (0.1% + 0.05sec) 
MEASUREMENT
AC/DC Voltage, KV 0 - 6.00 0.01 ± (2% of reading + 1count)
DC Voltage, KV (IR only) 0.10 - 1.00 0.01 ± (2% of reading + 2V) 
AC Current, mA 0.10 - 12.00 0.01 ± (2% of reading + 2counts) 
DC Current, mA 0.02 - 5.00 0.01 ± (2% of reading + 2counts) 
Resistance, MΩ 1 - 1000 (Auto Range) 0.001 0.01 0.1 ± (3% of reading+2counts)at > 500VDC ± (7% of reading +2counts)at < 500VDC
GENERAL
Input Voltage AC 110/220Vac± 15%, 50/60Hz ± 5%, Fuse 3A Fast
PLC Remote Control Input: Test, Reset
Output: Pass, Fail, Processing
Memory 5 Sets Store/Recall of each Memory, 4 Test Mode Selectable (W, I, W I, I W Only 7112, 7122)
Display 16× 2 LCD with back light
Key Lock To prevent unauthorized alteration of the test Parameters
Calibration Build-in software and external calibrated meters
Environment 0-40º C, 20-80%RH
Dimension/Net Weight 280mm(W)× 89mm(H)× 370mm(D)/ 9Kg
STANDARD ACCESSORIES
Power Cord(10A) × 1
Fuses × 3 (Including a spare contained in the fuse holder)
High Voltage Test Cable(1101) × 1