Product details
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer
Model |
WXE-60FS-12 |
WXE-60FS-24 |
WXE-60FS-36 |
DC Voltage |
12V |
24V |
36V |
Voltage Tolerance |
±3% |
±3% |
±3% |
Rated Current |
5A |
2.5A |
1.7A |
Current Range
|
0-5A |
0-2.5A |
0-1.7A |
Rated Power |
60W |
60W |
61W |
Ripple & Noise |
100 mVp-p |
150 mVp-p |
180 mVp-p |
DC Adjustment Range |
±10% |
±10% |
±10% |
Setup,Rise,Hold Time |
500ms,20ms,24ms/230VAC.800ms,30ms,20ms/115VAC at full load
|
|
|
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer Input Voltage Range 180~264 VAC 47~63 Hz;selected by switch 126~373VDC
AC Current 1.4A/115VAC 0.7A/230VAC
Efficiency 82%(FS-60-12); 84%(FS-60-24);85%(FS-60-36);
Inrush Current Cold start 35A/230VAC
Leakage Current
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer PROTECTION
Over Load
Protection type: recovers automatically after fault condition is removed
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer ENVIRONMENT
Working Temp., Humidity -10°C~+60°C;20%~90 %RH
Storage Temp., Humidity -20°C~+85°C;10%~95 %RH
Vibration 10~500Hz,2G 10min./1cycl, period for 60 min, each along X, Y, Z, axes
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer SAFETY
Withstand Voltage I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
WXE-60FS-48 mini Single output 60w constant current led dimmable electronic transformer led switching power supplies manufacturer STANDARD
Safety Standard Design refer to UL1012
EMC Standard Design refer to EN55022,CLASSA
OTHERS
Weight 0.60Kg
Packing: According to your order,we can provide different cartons for you.
NOTE
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ &47μ
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation